CAMPO EQUIPMENT MOFH280400 Manuel d'utilisation
Page 5

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com
2.) IN CANADA USE THE CSA B139 INSTALLATION CODE FOR OIL BURNING EQUIPMENT.
WIRING: ALL INTERNAL WIRING OF THE HEATER IS COMPLETED BY THE MANUFACTURER. ALL
EXTERNAL WIRING MUST CONFORM TO EXISTING ELECTRICAL CODES AS LAID DOWN BY THE
AUTHORITIES HAVING JURISDICTION. IN CANADA, REFER TO CSA C22.1 CANADIAN ELECTRICAL
CODE AND IN THE UNITED STATES AS OUTLINED IN THE BOCA CODE, OR THE NFPA 70 NATIONAL
ELECTRICAL CODE.
WARNING: LACK OF COMBUSTION AIR CAN CAUSE A DIRTY FIRE, ODOURS IN ENCLOSED
SPACES, AND BACKDRAFTING, POTENTIALLY RESULTING IN NAUSEA OR ASPHYXIATION OF
THE OCCUPANTS.
RATING AND PERFORMANCE.
Model: MOFH280-400
Pump Pressure (PSIG)
100 120 150
200
Input (BTU/h) with NO.1 fuel
277,000
310,240
339,325
391,955
Input (BTU/h) with NO.2 fuel
280,000 313,600 343,000
396,000
BECKETT BURNER
Nozzle (Delavan)
2 X 60B
2 X 60B
2 X 60B
2 X 60B
Combustion Air Adjustment
(shutter/band)
3/1
3/1
2/2
5/3
Head Setting
2 2 2
2
ELECTRICAL SYSTEM
Volts-Hertz-Phase
120-60-1
120-60-1
120-60-1
120-60-1
Full Load (Amps)
14.4 14.4 14.4
14.4
Max fuse size (Amps)
with time delay
2
2
2
2
FUEL TANK CAPACITY
35 IMPERIAL
GALLONS/42
U.S.
GALLONS
HEATED AIR WITHOUT DUCT 3500 CFM
APPROVAL AGENCY
OMNI
-
Test Laboratories, Inc.
DRY WEIGHT
480lbs
FLUE SIZE
6”
APPROXIMATE RUN TIMES WITHOUT USING RECIRCULATING DUCTS