Switching lever, 3 set the switching lever as above picture, Trigger – MAX NF565/16 Manuel d'utilisation

Page 10: Adjustment dial, Warning, 3 reconnect air supply, Contact tip

Advertising
background image

10

2

Turn the switching lever in the direction of the arrow.

3

Set the switching lever as above picture.

CONTACT TRIP
The common operating procedure on "Contact Trip" tools is for
the operator to contact the work to actuate the trip mechanism
while keeping the trigger pulled, thus driving a fastener each time
the work is contacted.
All pneumatic tools are subject to recoil when driving fasteners.
The tool may bounce, releasing the trip, and if unintentionally al-
lowed to recontact the work surface with the trigger still actuated
(finger still holding trigger pulled) an unwanted second fastener
will be driven.

DRIVING DEPTH ADJUSTMENT DIAL

ALWAYS-disconnect air supply before adjusting adjustment
dial.

1

If an adjustment is required, disconnect air supply.

2

Refer to the figure for direction to turn the dial.

3

Reconnect air supply.

THE CONTACT TIP

ALWAYS-disconnect air supply before setting the contact tip.
Set the contact tip on the top of the contact arm, when driving
nails to a soft material.

Use the contact tip at the back of the rear side of the magazine
as necessary.

Switching lever

Switching lever

Trigger

Contact arm

Adjustment dial

WARNING

Contact tip

Contact tip

WARNING

Advertising