INSTALLATION

INSTRUCTIONS

Standard Housing

IMPORTANT SAFETY

INFORMATION

(For Your Protection, Read Carefully)

1. Electric current can cause painful shock or

serious injury unless handled properly. For your

safety, always remember the following:

- Turn off the power supply.

- Ground the fixture to avoid potential electrical

shocks

.

- Do not handle an energized fixture or energize

any

fixture

with wet hands, when standing on a

wet or damp surface, or in water.

- Double check all electrical connections to

be sure they are tight and correct.

2. Specific safety information concerning lamps:

-Match wattage of fixture and lamp exactly.

- Do not remove or insert lamp when power is on.

- Do not scratch glass or subject lamp to undue

pressure as either may cause lamp breakage.

- Protect operating lamp from sources of

moisture.

Prior to Installation

Make certain that:
1. Ceiling opening is properly sized to accept housing.
2. Ceiling structure is properly constructed and supported.

3.

All supply leads meet applicable code.

NEW INSTALLATION

1.

Slide mounting rails into brackets

on housing. Mount fixture in ceiling as

shown.

2.

Position housing in ceiling opening

and align the bottom edge flush or slightly

above (1/8″ max.) the finished ceiling line.

Tighten all mounting hardware to assure

housing in secure.

Housing is now ready for Ballast assembly

and door.

DESCRIPTION

11"

12"

AVAILABLE ELECTRICAL

INSTALLED HOUSING

LAF 11 HSG

LAF 12 HSG

AVAILABLE LENS/DOOR

BA 2/130T (VOLTAGE)
BA 2/13TT (VOLTAGE)
BA 2/1801 (VOLTAGE)
BA 2/220T (VOLTAGE)
BA 2/260T (VOLTAGE)
BA 2/280T (VOLTAGE)

Prismatic

LA 11RW T73

LA 12FW T73

Semi-Flush Symmetric Lens

LA 11RW SFL

N/A

Drop Opal Lens'

LA 11RW DOL

N/A

White Aluminum Louver

LA 11RW ALE

N/A

Natural Aluminum Louver

LA 11RW ALN

NA

Flush Fresnel Lens

N/A

LA 12FW FR

Flat Holophane Lens

N/A

LA 12FW FHL

Drop Holophane Lens

N/A

LA 12FW DHL

16 Cell louver

N/A

LA 12SB 16A

9 Cell Louver

N/A

LA 12SB 9A

TROUBLE SHOOTING CHART

Check first for any visible damage to the lamp or frame-in module. If they seem in good condition, locate the problem

in the following list for possible cause and corrective action.

POSSIBLE CAUSE

CORRECTIVE ACTION

LAMP FAILS TO LIGHT

Circu

i

t

f

eeding

t

he fi

xt

ure n

ot

energi

z

e

d

W

i

ri

ng

err

or

in

c

ircu

i

t

o

r

modu

l

e con

n

ec

t

ion

Fau

l

ty

t

amp

Check

circuit b

r

eaker or fu

s

e

lo

I

nsure t

ha

t

c

ircuit i

s e

n

er

g

i

zed

.

Ex

a

mine

f

i

x

t

u

r

e

s

p

lice

b

o

x t

o se

e

t

ha

t

connec

ti

o

n

s are

proper.

Remove t

h

e

faulty

l

amp a

n

d

substitute

an

o

t

he

r

tamp

,

preferably o

n

e tha

t

is

kn

o

w

n

t

o li

gh

t.

If

the tamp

lig

ht

s,

r

ep

l

a

c

e

th

e or

i

g

i

na

l

w

i

t

h

a new one.

LAMP GOES OUT AFTER LIGHTING

Fau

l

ty

t

amp

Occasionally a lamp will exhibit this symptom rather than simply failing

to light. Substitute a new tamp

LAMP CYCLES ON AND OFF

Insulation is too close to fixture

Lamp wattage too high

Remove insulation from around module (at least3").

Install

tamp

wattage

s

p

ecified

I

n housi

n

g.

SAVE THESE INSTRUCTIONS

CJ520318 Rev. B 2/2014

Upon receipt, thoroughly inspect for any freight
damage which should be brought to the attention
of the delivery carrier. Compare the catalog
description listed on the packing slip with the label
on the carton to ensure you have received the
correct merchandise.

WARNING - RISK OF FIRE. DO NOT INSTALL
INSULATION WITHIN 3 INCHES OF FIXTURE
SIDES OR WIRING COMPARTMENT, NOR
ABOVE FIXTURE IN SUCH A MANNER AS TO
ENTRAP HEAT.