CJ5201016 Rev. B

2/2014 3 of 4

©2010 Acuity Brands Lighting, Inc.

All Rights Reserved.

SAVE THESE INSTRUCTIONS

Upon receipt, thoroughly inspect for any
freight damage which should be brought
to the attention of the delivery carrier.
Compare the catalog description listed on
the packing slip with the label on the
carton to ensure you have received the
correct merchandise.

INSTALLATION INSTRUCTIONS

AFLP/AFWLP Trim

IMPORTANT SAFETY INFORMATION

For Your Protection, Read Carefully

Warning: Risk of fire. Do not install
insulation within 3 inches of fixture
sides or wiring compartment, nor above
fixture in such a manner as to entrap
heat.

1. Electric current can cause painful
shock or serious injury unless handled
properly. For you safety, always
remember the following:

• Turn off the supply power.
• Ground the fixture to avoid potential
electrical shocks.
• Do not handle an energized fixture or
energize any fixture with wet hands,
when standing on a wet or damp surface,
or in water
2.

Specific

safety

information

concerning lamps:
• Match wattage of fixture and lamp
exactly.
• Do not remove or insert lamp when
power is on.
• Do not scratch glass or subject lamp to
undue pressure as either may cause
lamp breakage.
• Protect operating lamp from sources of
moisture.
• If lamp is marked

it contains

mercury. Follow disposal laws. See:
www.lamprecycle.org.

NEW INSTALLATION
1. Attach yoke under lanced up tabs on mounting frame as shown in Figure 1.
2. Attach socket housing to top of reflector by aligning/inserting socket housing into raised tabs on top of reflector.
Align screw on socket housing with keyhole slot in top of reflector and push socket housing forward as shown in
Figure 2. Secure socket housing and reflector together by tightening the screw.
3. Remove thumb nut from yoke.
4. Insert reflector through the ceiling opening making sure to tilt and rock reflector as shown in Figure 3 orienting
socket housing opposite the junction box. Align screw in yoke with keyhole slot in reflector assembly and attach
thumb nut as shown in Figure 4. Tighten thumb nut until the reflector is flush against the ceiling. For AFWLP trim,
make sure that the wallwash opening in the reflector is oriented with respect to the wall to be illuminated as shown
in Figure 5.
5. Install appropriate lamp by inserting tip of lamp through the opening opposite the socket housing, aligning base
of lamp with socket and snapping lamp into socket. Refer to label located inside socket cup for proper lamp type
and wattage.
6. To remove the reflector: remove lamp(s), remove thumb nut and disengage reflector. Tilt and rock reflector
through the ceiling opening, loosen screw and remove socket housing from reflector.

Figure 1

Figure 3

Figure 2

Figure 4

Figure 5

Wall

Wallwash

Opening

Thumb nut

Lanced tabs