Cleaning and Care

4

Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.

17T Series Installation

14

Adjust temperature limit stop! Turn on

water supplies; let the water run at both

full hot and full cold to ensure the water is

running as hot/cold as possible. Place a

thermometer in a plastic tumbler, and hold

the tumbler in the water stream. Place the

temperature knob (1) onto the splines (2),

then rotate the temperature knob until

you achieve your maximum desired

temperature from the outlet (not more

than 120° or the lower temperature

mandated by your local plumbing code).

Remove the temperature knob and replace

onto the splines (2), making sure that the

temperature knob limit stop (3) hits against

the volume handle limit stop (4) as shown.

Secure volume handle with set screw (5).

Secure the temperature knob using screw

(6) and place cap (7) on knob.

1

3

2

1

4

3

6

5

7

4

Care should be given to the cleaning

of this product. Although its finish is

extremely durable, it can be damaged by

harsh abrasives or polish. To clean, simply

wipe gently with a damp cloth and blot dry

with a soft towel.

Warning: Scrubbing Bubbles

®

Bathroom

Cleaner and Lysol

®

Basin Tub and Tile

Cleaner must not be used on the clear knob

handles and levers. Use of these cleaners

can result in cracked or severely damaged

handles. If overspray gets onto the handles,

immediately wipe them dry with a soft

cotton cloth