TROUBLESHOOTING

12

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Pilot will not light

Gas supply off

Check main / unit gas valves

Air in lines

Turn pilot valve on. Attempt to
light pilot every 15 sec.

Pilot valve not on

Turn pilot valve on / adjust

Burners won’t light

Gas supply off

Check main / unit gas valves

Air in lines

Turn gas valve on. Attempt to
light pilot every 15 sec.

Pilot burner not lit

Turn off gas - allow unit to
vent for 5 minutes. Turn gas
back on and light pilot

One burner assembly
won’t light

Control not on

Turn control knob to ON
Set to desired setting when lit

Water in burner

Remove burner and dry
thoroughly

Damaged gas control valve,
burner or other internal
component

Contact Authorized Wells
Service Agency for repairs

Portions of a burner won’t light or
have erratic flame

Burner wet or flame opening(s)
clogged

Clean and dry burner

Burner not hot enough

Temperature control not set

Adjust for desired temperature

Shutter or nozzle out of
adjustment

Contact qualified technician for
adjustment

Damaged gas control valve,
burner or other internal
component

Contact Authorized Wells
Service Agency for repairs

NOTE: There are no user serviceable components in the burner assemblies or in the control valves.