Installation instructions, Warning, Prepare location – Whirlpool W10240546A Manuel d'utilisation

Page 7

Advertising
background image

7

INSTALLATION INSTRUCTIONS

Prepare Location

NOTE: For vented installations, it is recommended that the vent
system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.

1. For vented installations, determine which venting method to

use: roof or wall.

2. Select a flat surface for assembling the range hood. Place

covering over that surface.

3. Using 2 or more people, lift the range hood onto covered

surface.

4. If cabinet has recessed bottom, add wood filler strips on each

side. Install screws to attach filler strips in locations shown.

Determine Wiring Hole Location

Cut only one 1

¹⁄₄" (3.2 cm) diameter wiring access hole. See Step

2 for wiring hole location instructions. Either wiring hole can be
used.

1. Determine and clearly mark a vertical centerline on the wall

and cabinet in the area the vent opening will be made.

2. To wire through top:

Mark a line 7½" (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 1¼" (3.0 cm) diameter hole
through the cabinet at this point.

To wire through rear wall:

Mark a line 7½" (19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is ¾" (1.9 cm) from
underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole
through wall at this point.

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System

Roof Venting

To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout on
the underside of cabinet top and bottom:

1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall

on the centerline of the underside of cabinet.

2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline

on the underside of cabinet.

3. Use saber or keyhole saw to cut a rectangular opening for

vent.

4. Repeat steps 1-3 for the underside of the top of the cabinet.

A. Centerline

WARNING

Excessive Weight Hazard

Use two or more people to move and install
range hood.

Failure to do so can result in back or other injury.

Cabinet
bottom

Wall

3" (7.6 cm)

Wood filler strips

(recessed cabinet

bottoms only)

3" (7.6 cm)

A

Centerline

2" (5.1 cm)
from wall,
not cabinet
frame

7

¹⁄₂

"

(19 cm)

7

¹⁄₂

"

(19 cm)

Centerline

³⁄₄

" (1.9 cm)

5

¹

/

"

(13.3 cm)

5

¹

/

"

(13.3 cm)

*5

¹

/

"

(14 cm)

*From wall, not cabinet frame

Cabinet cutouts

*1

¹

/

" (3.8 cm)

Advertising
Ce manuel est liée aux produits suivants: