Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure. Do not use screws or other
fastening devices that extend into the interior of the vent to
secure vent.

Terminate the exhaust vent outside. The exhaust vent must not
terminate beneath the mobile home and must not be connected
to any other duct, vent, or chimney.

Determine Vent length

1. Select the route that will provide the staightest and most

direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns.

2. Determine vent length.

The maximum length of the exhaust system depends upon:

The type of vent (rigid metal or flexible metal).

The number of elbows used.

Type of hood.

Recommended hood styles are shown here.

1. Louvered style

2. Box hood style

The angled hood style (shown following) is acceptable.

See the exhaust vent length chart that matches your hood type
for the maximum vent lengths you can use.

Exhaust systems longer than specified will:

Shorten the life of the dryer.

Reduce performance, resulting in longer drying times and
increased energy usage.

3. Determine the number of elbows you will need.

IMPORTANT: Do not use vent runs longer than specified in the
Vent Length Chart

In the column listing the type of metal vent you are using (rigid
metal or flexible metal), find the maximum length of metal vent on
the same line as the number of elbows.

Install Vent System

1. (Optional) Put on safety glasses and gloves.

2. Before installing the vent system, be sure to remove the wire

exhaust guard that is located at the exhaust outlet.

3. Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

4. Connect vent to exhaust hood. Vent must fit inside exhaust

hood. Secure vent to exhaust hood with 4 in. (10.2 cm)
clamp.

5. Run vent to dryer location. Use the straightest path possible.

See “Determine Vent Length.” Avoid 90º turns. Use duct tape
to seal all joints.

4"
(10.2 cm)

4"
(10.2 cm)

1

2

4"

(10.2 cm)

2.5"

(6.4 cm)

Number of

90º turns

or elbows

Type of

vent

Box or

louvered

hoods

Angled

hoods

0

Rigid metal

Flexible metal

36 ft (11 m)
28 ft (8.5 m)

26 ft (7.9 m)
22 ft (6.7 m)

1

Rigid metal

Flexible metal

26 ft (7.9 m)
18 ft (5.5 m)

16 ft (4.9 m)
12 ft (3.7 m)

2

Rigid metal

Flexible metal

16 ft (4.9 m)
8 ft (2.8 m)

6 ft (1.8 m)
2 ft (0.6 m)