Warning, Make electrical connection, Install range hood – Whirlpool 9763375 Manuel d'utilisation

Page 8: Install vent (for vented installations only)

Advertising
background image

Make Electrical Connection

1. Disconnect power.

2. Remove terminal box cover.

3. Remove the knockout in terminal box cover and install the

UL-or CSA-listed

¹⁄₂" conduit.

4. Run 3 wires, black, white and green (14AWG) in

¹⁄₂" conduit

from service panel to terminal box.

5. Use twist-on connectors and connect black wires together.

6. Use twist-on connectors and connect white wires together.

7. Use twist-on connectors and connect green or bare wire with

yellow-green wire.

8. Replace terminal box cover.

9. Check all light bulbs to make sure they are secure in their

sockets.

10. Reconnect power.

8

Install Range Hood

1. Hang hood on 2 mounting hooks through the rectangular

cutouts on back of hood.

2. Level the hood with leveling screws in mounting hooks or

rectangular cutouts, using a level across bottom of hood.

3. Secure hood with 4 screws through remaining 4 holes in hood.

Install Vent (for vented installations only)

1. Fit vent system over transition piece.

2. Seal connection with duct tape.

A

A. Conduit

A

A. Transition

WARNING

Excessive Weight Hazard

Use two or more people to move and install range hood.

Failure to do so can result in back or other injury.

B

B

D

C

A, Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall

A

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire
in terminal box.

Failure to do so can result in death or electrical shock.

Advertising