Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.

If the house has aluminum wiring follow the procedure below:

1. Connect a section of solid copper wire to the pigtail

leads.

2. Connect the aluminum wiring to the added section of

copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.

Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the hood.

Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

NOTE: For vented installations, it is recommended that the vent
system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.

Preparation

1. For vented installations, determine which venting method to

use: roof or wall.

2. Select a flat surface for assembling the range hood. Place

covering over that surface.

3. Using two or more people, lift the range hood onto covered

surface.

4. If cabinet has recessed bottom, add wood filler strips on each

side. Install screws to attach filler strips in locations shown.

Determine Wiring Hole Location

Cut only one 1

¹⁄₄" (3.2 cm) diameter wiring access hole. See Step

2 for wiring hole location instructions. Either wiring hole can be
used.

1. Determine and clearly mark a vertical centerline on the wall

and cabinet in the area the vent opening will be made.

WARNING

Excessive Weight Hazard

Use two or more people to move and install
range hood.

Failure to do so can result in back or other injury.

Cabinet
bottom

Wall

3" (7.6 cm)

Wood filler strips

(recessed cabinet

bottoms only)

3" (7.6 cm)

A. Centerline

A