RULES FOR SAFE INSTALLATION

RULES FOR SAFE INSTALLATION

RULES FOR SAFE INSTALLATION

RULES FOR SAFE INSTALLATION

RULES FOR SAFE INSTALLATION
AND OPERATION

AND OPERATION

AND OPERATION

AND OPERATION

AND OPERATION

1. Read the Owners Manual and the Rules for Safe

Operation carefully. Failure to follow these rules and
instructions could cause a malfunction of filter or
unsatisfactory service.

2. Follow a regular service and maintenance schedule for

efficient operation.

PLACEMENT

PLACEMENT

PLACEMENT

PLACEMENT

PLACEMENT

The installer must be qualified to make approved electrical
connections and a safe ceiling installation with attention to the
best placement as shown in the following drawings.

The electronic air cleaner should be mounted in the center of the
room. Air is drawn through the bottom grille and discharged
through the four side grilles. Divide larger rooms into sections
and use a unit in each section (Fig. 2).

Check existing air circulation in the room. The air cleaner should
be installed so that it aids the circulation already established.
When air flow patterns are not immediately apparent, observe
the smoke from a cigarette in various locations within the room.
Do not locate the air cleaner near a heating or air conditioning
intake or exhaust vent if it interferes with the air flow discharge
and return air to the heating or air conditioning unit.

CEILING MOUNT

CEILING MOUNT

CEILING MOUNT

CEILING MOUNT

CEILING MOUNT

The air cleaner is mounted by suspending it from the building
structure above the suspended ceiling. The mounting holes are
spaced 21” and 15

3

/

4

” between centers (Fig. 3).

COLLECTING

PLATES

CLEAN

AIR

OUT

CLEAN

AIR

OUT

IONIZING SECTION

IONIZING WIRES GIVE DIRT

PARTICLES A POSITIVE CHARGE

CHARCOAL FILTER

REDUCES ODOR

COLLECTING SECTION

COLLECTOR PLATES ATTRACT

AND HOLD DIRT PARTICLES

LIKE A MAGNET

DIRTY
AIR IN

3

8

3

8

3

4

3

4

3

4

1

1

23

21

4

4

15

23

Mounting Detail

Mounting Detail

Mounting Detail

Mounting Detail

Mounting Detail

Select a mounting location where the structure above is strong
enough to support the weight of approximately 50 lbs (Fig.4 &
5).

CAUTION: Do not allow the unit to be supported by the

CAUTION: Do not allow the unit to be supported by the

CAUTION: Do not allow the unit to be supported by the

CAUTION: Do not allow the unit to be supported by the

CAUTION: Do not allow the unit to be supported by the
ceiling tile grid suspension.

ceiling tile grid suspension.

ceiling tile grid suspension.

ceiling tile grid suspension.

ceiling tile grid suspension.

3/8" DIA. STEEL

THREADED ROD

COVER

WELD NUT

CEILING GRID
(DO NOT USE

FOR SUPPORT)

CEILING GRID

(DO NOT USE

FOR SUPPORT)

2X4

ROOF SUPPORT JOIST

NUT & WASHER TOP AND BOTTOM

FIG

FIG

FIG

FIG

FIG..... 1 Illustr

1 Illustr

1 Illustr

1 Illustr

1 Illustra

a

a

a

ation of

tion of

tion of

tion of

tion of Air Cleaning Pr

Air Cleaning Pr

Air Cleaning Pr

Air Cleaning Pr

Air Cleaning Process

ocess

ocess

ocess

ocess

FIG

FIG

FIG

FIG

FIG..... 2 Mount the unit on the ceiling a

2 Mount the unit on the ceiling a

2 Mount the unit on the ceiling a

2 Mount the unit on the ceiling a

2 Mount the unit on the ceiling at the center

t the center

t the center

t the center

t the center

of

of

of

of

of ar

ar

ar

ar

area to be c

ea to be c

ea to be c

ea to be c

ea to be cleaned.

leaned.

leaned.

leaned.

leaned.

FIG

FIG

FIG

FIG

FIG..... 3

3

3

3

3 A

A

A

A

Appr

ppr

ppr

ppr

ppro

o

o

o

oxima

xima

xima

xima

ximate Installa

te Installa

te Installa

te Installa

te Installation Dimensions in Inc

tion Dimensions in Inc

tion Dimensions in Inc

tion Dimensions in Inc

tion Dimensions in Inches

hes

hes

hes

hes

FIG

FIG

FIG

FIG

FIG..... 4

4

4

4

4

FIG

FIG

FIG

FIG

FIG..... 5

5

5

5

5

Advertising