Plan vent system – Whirlpool Cabrio W10164752A Manuel d'utilisation

Page 8

Advertising
background image

8

Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.

Do not install flexible metal vent in enclosed walls, ceilings or
floors.

Elbows

45° elbows provide better airflow than 90° elbows.

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.

Exhaust

Recommended hood styles are shown here.

The angled hood style (shown here) is acceptable.

An exhaust hood should cap the vent to keep rodents and
insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer.

Standard exhaust installation with rigid metal or flexible
metal vent

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.
Refer to the manufacturer’s instructions.

NOTE: The following kits for close clearance alternate
installations are available for purchase. Please see the
“Assistance or Service” section to order.

Over-the-Top Installation:

Part Number 4396028

Good

Better

Clamp

A. Louvered hood style
B. Box hood style

4"
(10.2 cm)

4"
(10.2 cm)

B

A

4"

(10.2 cm)

2½"

(6.4 cm)

Improper venting can cause moisture and lint to collect
indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.

Housecleaning problems and health problems.

A. Dryer

B. Elbow

C. Wall
D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet

A. Over-the-top installation (also available with one offset

elbow)

B. Periscope installation

C. Rear exhaust installation to left or right side

A

B

B

C

D

E

F

G

H

A

B

C

Advertising