USE AND CARE

Disconnect electrical power supply and lock out
service panel before cleaning or servicing this unit.

CLEANING

Remove cover and carefully vacuum blower and
inside of housing. Be careful not to bend or otherwise
damage blower wheel.

MOTOR LUBRICATION

The motor is permanently lubricated. Do not oil or
disassemble motor.

INSTALL THE ROUGH-IN PLATE

1. Run 10" round steel ductwork, from exterior blower

to the installation location. For best performance,
use the straightest possible duct run and the few-
est number of elbows. Tape all joints.

2. Run 120 VAC electrical power cable from service

panel and from remote blower to installation loca-
tion.

3. Remove wiring box cover. Remove knockouts

from the wiring box. Feed 6" of power cable through
openings and attach cables to wiring box with
appropriate connectors.

4. Wire black to black, white to white, and green or

bare wire beneath green ground screw. Replace
wiring box cover.

5. Attach rough-in plate to the studs at the inside top

of hood with (4) #10-24 nuts provided.

6. Connect ductwork to rough-in plate and tape joint.

GREEN

WHITE

BLACK

GREEN

WHITE

BLACK

BLACK

WHITE

GREEN

BLACK

WHITE

GREEN

ROUGH-IN PLATE LEAD

ROUGH-IN PLATE LEAD

WIRING BOX

LINE IN

120 VAC

60 HZ

10 A MAX.

EXTERIOR

BLOWER

VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA

10" ROUND

DUCT

POWER

CABLE

WIRE

BOX

COVER

HOUSE

WIRING

7. Turn on power and check blower operation.

10" DAMPER

MOUNTS INSIDE

DUCTWORK AT

LEAST 3" ABOVE

CANOPY OUTLET

Advertising