Prepare the installation location, Prepare the ventilator – Viking DEV900 Manuel d'utilisation

Page 2

Advertising
background image

2

11" dia.

hole

29½"

11" dia.

hole

1¼"

dia. hole

12

7

/

8

"

10¾"

25"

7¼"

7¼"

1¼"

dia. hole

9

1

/

8

"

9

1

/

8

"

W

a

ll

S

tu

d

10¾"

24¾"

28¼"

W

a

ll Stud

12

7

/

8

"

W

a

ll

S

tu

d

W

a

ll Stud

REMOVE

SIDING

REMOVE

SIDING

8½"

8½"

Pilot

Pilot

Hole

Hole

Pilot

Hole

OUTSIDE - WALL VIEW

OUTSIDE - WALL VIEW

1. Locate the ventilator on the rear slope of the roof.

Place it in a location to minimize duct run. The
location should be free of obstacles (T.V. leads,
electrical lines, etc.). Bear in mind, if the ventilator
top is level with the roof peak, it will not be seen
from the street. Keep this approximate location in
mind as you work from within the attic.

1. Choose a position on the outside wall. Make sure

that no wall studs, pipes or wires run through the
opening area.

PREPARE THE INSTALLATION
LOCATION

ROOF INSTALLATIONS

PREPARE THE INSTALLATION
LOCATION

WALL INSTALLATIONS

ALL INSTALLATIONS

5. For flat roof installations, build a curb that will

mount the ventilator at a minimum pitch of 2/12.
See Figure 2. Discharge end of the ventilator
should be pointed away from prevailing winds.

20½"

11"

dia.

hole

20½"

10

3

/

8

"

1¼"

dia. hole

10

3

/

8

"

8½"

8½"

20¾"

20¾"

7¼"

7¼"

1¼"

dia. hole

9

1

/

8

"

9

1

/

8

"

REMOVE

SHINGLES

Roof Rafter

REMOVE

SHINGLES

11"

dia.

hole

Roof Rafter

Pilot

Pilot
Hole

Hole

Pilot
Hole

OUTSIDE - ROOF VIEW

OUTSIDE - ROOF VIEW

From inside the attic space:
2.

Drill a PILOT HOLE up through the roof, 8½"
from the

inside edge of a ROOF RAFTER.

From outside - on the roof:
3.

Measure and mark the 20¾" x 20½" rectangle.
Cut and remove only the shingles inside this
rectangle.

4.

Measure and mark the 11" DIAMETER HOLE
and the 1¼" DIAMETER HOLE. Cut these holes
all the way through the roof.

Figure 1

PREPARE THE VENTILATOR

1. Unpack the ventilator assembly.

2. Remove the cover and screws.

3. Remove and discard cardboard from ventilator

wheel.

4. Remove the wiring box cover and screws.

5. Attach an appropriate U.L. approved cable con-

nector in the hole at the rear of the wiring box.

From inside the wall:
2.

Drill a PILOT HOLE through the wall, 8½" from
the

inside edge of a WALL STUD.

From outside - on the wall:
3.

Measure and mark the 25" x 29½" rectangle. Cut
and remove only the siding inside this rectangle.

4.

Measure and mark the 11" DIAMETER HOLE
and the 1¼" DIAMETER HOLE. Cut these holes
all the way through the wall.

Figure 3