1. Run 10" round steel ductwork, from exterior ventilator to

the installation location. For best performance, use the
straightest possible duct run and the fewest number of
elbows. Tape all joints.

2. Run 120 VAC electrical power cable from service panel

and from remote ventilator to installation location.

3. Remove wiring box cover. Remove knockouts from the

wiring box. Feed 6" of power cable through openings and
attach cables to wiring box with appropriate connectors.

VIKING RANGE CORPORATION

GREENWOOD, MISSISSIPPI 38930 USA

4. Wire black to black, white to white, and green or bare wire

beneath green ground screw. Replace wiring box cover.

5. Connect ductwork to transition and tape joint.

6. Turn on power and check ventilator operation.

INSTALL THE ROUGH-IN PLATE

USE AND CARE

Disconnect electrical power supply and lock out service
panel before cleaning or servicing this unit.

CLEANING

Remove cover and carefully vacuum ventilator and inside of
housing. Be careful not to bend or otherwise damage
ventilator wheel.

MOTOR LUBRICATION

The motor is permanently lubricated. Do not oil or
disassemble motor.