Appendixes, Appendix b. utp/stp connection, Rj45 8-pin pin wire color wire pair – Rose electronic Crystal View Manuel d'utilisation
Page 45
Advertising

APPENDIXES
CrystalView Installation and Operations Manual
39
Appendix B. UTP/STP Connection
The Local and Remote connection cable is terminated with RJ45 connectors and
must be wired according to the EIA/TIA 568 industry standard. Scheme B is
preferred.
RJ45 8-Pin
PIN
Wire Color
Wire Pair
1
White/Orange
T2
2
Orange/White
R2
3
White/Green
T3
4
Blue/White
R1
5
White/Blue
T1
6
Green/White
R3
7
White/Brown
T4
8
Brown/White
R4
The CrystalView has been tested with all major makes of CAT-5 cables, including
BICC-VERO, Mohawk and AT&T.
The CrystalView has also been tested on CAT-3 cable and on pairs within a 25-
pair UTP trunk cable.
Assure that the CAT-5 cable is a “Solid Core” cable.