Lennox Hearth E36ODG Manuel d'utilisation

Four Lennox Hearth

Advertising
background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

GAS APPLIANCE

KITS AND ACCESSORIES

GAS CONVERSION KIT

Figure 1

In Canada:
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1
AND .2 INSTALLATION CODE.

LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDATIONS
DES AUTORITÉS PROVINCIALES AYANT
JURIDICTION ET CONFORMÉMENT AUX
EXIGENCES DU CODE D'INSTALLATION CAN1-
B149.1 ET.2.

Gas conversion kits are available to adapt your
appliance from the use of one type of gas to the
use of another. These kits contain all the nec-
essary components needed to complete the
task including labeling that must be affixed to
ensure safe operation.

Kit part numbers are listed here and the follow-
ing steps detail the conversion procedure.

CAUTION: THE GAS SUPPLY SHALL BE SHUT
OFF PRIOR TO DISCONNECTING THE ELEC-
TRICAL POWER, BEFORE PROCEEDING WITH
THE CONVERSION.

WARNING: THIS CONVERSION KIT SHALL BE
INSTALLED BY A QUALIFIED SERVICE AGENCY IN
ACCORDANCE WITH THE MANUFACTURER'S IN-
STRUCTIONS AND ALL APPLICABLE CODES AND
REQUIREMENTS OF THE AUTHORIZED HAVING
JURISDICTION. IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A
FIRE, EXPLOSION OR PRODUCTION OF CARBON
MONOXIDE MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
THE INSTALLATION IS NOT PROPER AND COM-
PLETE UNTIL THE OPERATION OF THE CONVERTED
APPLIANCE IS CHECKED AS SPECIFIED IN THE
OWNER INSTRUCTIONS SUPPLIED WITH THE KIT.
THE QUALIFIED SERVICE AGENCY PERFORMING
THIS INSTALLATION ASSUMES RESPONSIBILITY
FOR THIS CONVERSION.

AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION
SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE
CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET
TOUTES EXIGENCES ET CODES APPLICABLES DE
L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION
DANS CETTE INSTRUCTION N'EST PAS SUIVIE
EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE
PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES
CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE
PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE
EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET
ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET
COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL
CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS
DANS LES INSTRUCTIONS DE PROPRIÉTAIRE
PROVISIONNÉES AVEC L'ÉQUIPEMENT.

Step 1. Turn off the gas supply to the appli-
ance and disconnect the electrical power.

Step 2. Carefully remove the logs. Exercise
care so as not to break the logs
. Remove any
lava rock within the burner pan.

Step 3. Remove the burner tube with attached
venturi tube. Refer to

Figure 1 for the location

of the control valve and regulator, main orifice
and pilot.

750,222M
REV. A 07/2006

Access

Cover

Control Valve
And Regulator

Pilot Orifice

Burner Tube

Main

Orifice

s

t

i

K

n

o

i

s

r

e

v

n

o

C

s

a

G

s

l

e

d

o

M

t

a

N

o

T

P

L

P

L

o

T

t

a

N

G

D

O

6

3

E

G

D

O

2

4

E

.

o

N

g

o

l

a

t

a

C

5

1

9

4

H

.

o

N

g

o

l

a

t

a

C

6

1

9

4

H

G

D

O

6

3

E

G

D

O

2

4

E

.

o

N

l

e

d

o

M

N

0

4

1

B

D

-

K

C

G

.

o

N

l

e

d

o

M

P

8

7

0

B

D

-

K

C

G

Advertising
Ce manuel est liée aux produits suivants: