Electrical connection, Warning, Wire connections chart check operation – KITCHENAID 8285364 Manuel d'utilisation

Page 7

Advertising
background image

7

Electrical

connection

Electrical Shock Hazard

Turn power supply off before
connecting wires.

Use 10-gauge solid copper wire.

Electrically ground cooktop.

Failure to follow these
instructions can result in death,
fire, or electrical shock.

WARNING

This cooktop must be connected to a
grounded, metallic permanent wiring
system or a ground connector should be
connected to the ground terminal or wire
lead on the cooktop.

This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through
the 1/2" (12.7 mm) U.L.-listed conduit
connector. Complete electrical connection
according to local codes and ordinances.

5.

Make the electrical connection:

1. Disconnect the power supply.
2. Remove the junction box cover from junction

box inside cabinet.

3. Connect cooktop power supply cable to

junction box using a U.L.-listed conduit
connector. Tighten screws on conduit
connector.

4. Connect the two black wires together with

twist-on connectors.

5. Connect the two red wires together with

twist-on connectors.

6. Complete the electrical connection

according to local codes and ordinances.
(See "Wire connections chart.")

If local codes DO NOT PERMIT

connecting cooktop-ground

conductor to neutral white wire

in junction box:

(four-wire system)

If local codes PERMIT

connecting cooktop-ground

conductor to neutral

junction box wire:

(three-wire system)

Figure 1

power supply
cable from cooktop

junction
box

U.L.-listed
conduit
connector

red
wires

white
wire

black
wires

green ground
appliance cable
wire

green or
bare
ground
wire

Figure 2

junction
box

red
wires

white
wire

cable from fused disconnect
or circuit breaker box

black
wires

power supply cable
from cooktop

U.L.-listed
conduit
connector

7. Connect the green power supply

cable wire to the neutral (white) wire
in junction box with twist-on
connector. See Figure 2.

8. Replace junction box cover.

7. Connect the green ground power

supply cable wire to the ground wire
in junction box or other ground
connector with twist-on connector.
See Figure 1.

8. Put a twist-on connector on end of

white wire.

9. Replace junction box cover.

green ground
appliance cable
wire

cable from fused disconnect
or circuit breaker box

Wire connections chart

Check operation

You have just finished installing your
new KitchenAid downdraft cooktop.
To get the most efficient use from
your new cooktop, read your Use &
Care Guide.
Keep Installation Instructions and
Guide close to cooktop for easy
reference.

6.

Turn on electrical supply.

7.

Check that cooktop surface elements

heat and indicator lights are operating
correctly.

8.

Check that downdraft vent operates.

If the cooktop does not operate, disconnect the
power supply and check that wire connections
have been made correctly.