Troubleshooting – Schumacher 600A Manuel d'utilisation
Page 11

11
TROUBLESHOOTING
Performance problems often can be corrected by the user. Please completely read
this chart for possible solutions to common problems.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Check (red) light is on.
The battery is not connected
Connect or adjust clips.
correctly.
Check for correct polarity.
The CHARGE RATE and
Press the button to select
CHARGE TYPE buttons were the correct rate and type.
not selected.
The battery is less than one
Replace the battery or try
volt.
using a manual charger to
bring above 1V.
Indicator lights are lit in an
A button may have been
Make sure nothing is touching
erratic manner not explained
pressed while the charger
the control panel, then unplug
in the “Using Your Battery
was plugged in.
the unit and plug it in again.
Charger” section.
The charger may be
Return to place of purchase
defective.
for replacement.
The CHECK (red) light is
Charger in abort mode.
See “USING YOUR BATTERY
flashing.
Battery may be bad.
CHARGER.”
Battery type may have been
Unplug the charger and select
set for 6 volts on a 12 volt
the correct battery voltage.
battery.
The CHECK (red) light always This will happen if the battery Reset the charger by
flashes before the battery is
did not reach full charge
unplugging it. Select the
completely charged.
within 24 hours. May be due
desired charge rate and
to a very large battery or a
battery type again, if
bank of batteries requiring
necessary.
more power than the charger
can deliver in 24 hours.
Battery may also be faulty.
The green CHARGED light
The battery may be fully
If the battery is in a vehicle,
turns on a few minutes after
charged or recently charged,
turn the headlights on for a
connecting to the battery.
leaving the battery voltage
few minutes to reduce the
high enough to appear to be
battery voltage and try
fully charged.
charging again. Also try a
lower CHARGE RATE
selection.
The charger is making an
The charger has a relay that
No problem, this is a normal
audible clicking sound.
turns the current on and off
condition.
to the battery.
The measured current is
The charger reached the
No problem, this is a normal
much lower than what
maximum voltage and is
condition.
was selected.
reducing the current.