Install the Discharge Chute

NOTE: Some models have the discharge chute already

installed.

Place discharge chute (

1.

M, Figure 5) over tabs on chute

ring (N) as shown.

Secure discharge chute with three carriage bolts (

2.

O) and

nuts (P).

Figure 5

Route Defl ector Cable & Clip (if included)

Figure 6

Figure 7

Figure 4

L

NOTE: If the chute rotation is slow or binding, loosen the

chute rotation screws (L, Figure 4) 1/4 turn.

M

N

O

P

P

P

3. Tighten hardware to 66 in-lbs (7.6 Nm).

4. Connect the wire harness (electric chute models only).

NOTE: Check all bolts and nuts in fl ange for tightness. Do not

overtighten.