INITIAL SET-UP:
. Read safety warnings before setting-up air compressor.
. Ensure the oil level in the air compressor pump is adequate. If low,
add SAE-30W non-detergent oil.
LOCATION:
. In order to avoid damaging the air compressor, do not incline the air
compressor transversely or longitudinally more than 0°.
. Place air compressor on a concrete surface at least inches away from
obstacles that may prevent proper ventilation. Place the flywheel side
of the unit toward the wall. Do not place air compressor in an area:
-where there is evidence of oil or gas leaks.
-where flammable gas vapors or materials may be present.
-where air temperatures fall below 3°F or exceed 04°F.
-where extremely dirty air or water could be drawn into the air
compressor.
3. Distribute air compressor weight evenly. Excessive vibration can weaken
the air tank creating a hazard of explosion.
4. Bolt the air compressor to the concrete surface.
a. Mark the areas through the feet of the air compressor where anchor
bolts will be placed.
b. Move the air compressor and drill holes in the marked areas to
accept the anchor bolts.
c. With the nut attached, pound the anchor bolts into the pre-drilled
holes.
d. Remove the nuts and place the air compressor over the anchor
bolts.
e. Replace and tighten the nuts.
PREPARATION INSTRUCTIONS
WARNING
RISK OF EXPLOSION OR FIRE
CAUSING SERIOUS INJURY
OR DEATH!
Do not allow the motor or Motor/
Pressure Switch to come in
contact with flammable vapors,
combustible dust, gases or other
combustible materials. An electric
spark may cause an explosion
or fire.
When using the air compressor
for spray painting, place the air
compressor as far away from the
work area as possible.
ANCHOR-DCE