INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Parts supplied

Check that all parts are included.

Anti-tip bracket kit

NOTE: Anti-tip bracket must be securely mounted to subfloor.
Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your local
hardware store. See “Install Anti-Tip Bracket” section.

Gas pressure regulator

Burner grates

Burner heads and caps

Griddle drip tray (on griddle models)

LP orifice package (W10323791)

Conversion label (8114P522-60)

NOTE: The cooktop is manufactured for use with Natural gas. To
convert to LP gas, see the “Gas Conversions” section.

Parts needed

All models must be installed with a backguard if installing at zero
clearance to a combustible backwall. See “Cabinet Dimensions”
in the “Location Requirements” section for installation
requirements.

30" (76.2 cm) Adjustable Backguard
Order Part Number 8285148

36" (91.4 cm) Adjustable Backguard
Order Part Number 8284756

48" (121.9 cm) Adjustable Backguard
Order Part Number 8284755

22" (55.9 cm) Backsplash with Dual-Position Shelf for
30"(76.2 cm) Ranges
Order Part Number W10285447

22" (55.9 cm) Backsplash with Dual-Position Shelf for
36" (91.4 cm) Ranges
Order Part Number W10285448

22" (55.9 cm) Backsplash with Dual-Position Shelf for
48" (121.9 cm) Ranges
Order Part Number W10285449

To order, see the “Assistance or Service” section of the Use
and Care Guide.

Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.

It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.

High Altitude Conversion

To convert the range for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.

Part Number W10324363 - LP high altitude

Part Number W10324365 - Natural gas high altitude

To order, see the “Assistance or Service” section of the Use and
Care Guide.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.

Connect anti-tip bracket to wall behind range.

Reconnect the anti-tip bracket, if the range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.

Tape measure

#2 Phillips screwdriver

¹⁄₈" x 4¼" flat-blade
screwdriver

Level

Drill

Wrench or pliers

Pipe wrench

Adjustable wrench or

⁵⁄₈" wrench

³⁄₈" drive ratchet

¹⁄₈" drill bit

¹⁵⁄₁₆" combination wrench

¹⁄₄", ³⁄₈", ⁵⁄₁₆" nut drivers

³⁄₁₆" carbide tip masonry bit

Marker or pencil

Pipe-joint compound
resistant to LP gas

Noncorrosive leak-detection
solution

Tubing cutter

For LP/Natural Gas
Conversions

T15 Torx

®†

screwdriver

⁷⁄₈" socket

Adjustable wrench

½" deep-well socket

7 mm nut driver

Masking tape

A. Anti-tip bracket
B. #8-18 x 1" Phillips head screws (4)

†®TORX is a registered trademark of Saturn Fasteners, Inc.

A