Installation requirements, Tools and parts, Location requirements – Jenn-Air W10197058B Manuel d'utilisation

Page 3

Advertising
background image

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.

Tools needed

Parts supplied

Parts needed

Metal ducting

Vent clamps

Jenn-Air wall cap

Jenn-Air

®

6" (15.2 cm) Round Surface Wall Cap Damper

Order Part Number A406

Jenn-Air

®

3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper

Order Part Number A403

To order, see the “Assistance or Service” section of the Use
and Care Guide.

Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.

It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.

It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on side of the downdraft
plenum.

To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.

The cooktop should be installed in a location away from
strong draft areas, such as windows, doors and strong
heating vents or fans.

All openings in the wall or floor where cooktop is to be
installed must be sealed.

Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical
Requirements” section. Proper gas supply connection must
be available. See “Gas Supply Requirements” section.

The cooktop is designed to hang from the countertop by its
side or rear flanges.

The gas and electric supply should be located as shown in
“Cabinet Dimensions” section so that they are accessible
without requiring removal of the cooktop.

Provide cutout in right rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord,
and to allow the rating label to be visible.

If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.

IMPORTANT: An undercounter built-in oven cannot be installed
under this product.

IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the
Manufactured Home Construction and Safety Standard, Title 24
CFR, Part 3280 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or local codes.

In Canada, the installation of this cooktop must conform with
the current standards CAN/CSA-A240-latest edition, or with
local codes.

Product Dimensions

30" (76.2 cm) Cooktop

Tape measure

Flat-blade screwdriver

Phillips head screwdriver

Drill

Level

6" (15.2 cm) socket
extension

Marker or pencil

Pliers

¼" drill bit

Jigsaw

Ratchet with

³⁄₈" socket

Pipe-joint compound
resistant to LP gas

Noncorrosive leak-detection
solution

Vent grill

Pre-filter

LP conversion kit

Burner caps

Burner grates

Pressure regulator

A. 21½" (54.6 cm)
B. 19

¹¹⁄₁₆

" (50.0 cm)

C. Model/serial rating plate location

C

A

B

Advertising