5

Parts needed

For vented installations, you will also need:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also
need:

Recirculation Kit Part Number W10272063 for non-vented
(recirculating) installations only. See “Assistance or Service”
section to order.

6" (15.2 cm) dia. round metal vent duct - length required is
determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs
installed

Vent transition with back draft dampers installed

Metal grease filter(s)

Vent cover support bracket

Mounting template

2-piece vent cover

2 - 3.5 x 6.5 mm screws

2 - 2.9 x 6.5 mm screws

6 - 5 x 45 mm mounting screws

2 - 8 x 40 mm wall anchors

4 - 10 x 50 mm wall anchors

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.

Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical
Requirements” section.

The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see “For Non-
vented (recirculating) Installations Only” in “Connect Vent
System” section. Recirculation Kit Part Number W10272063 is
available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where canopy hood will be
installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.

Product Dimensions

*For non-vented (recirculating) installations

**For vented installations

Cabinet Dimensions

*For non-vented (recirculating) installations

*NOTE: The range hood chimneys are adjustable and designed

to meet varying ceiling or soffit heights depending on the
distance “X” between the bottom of the range hood and the
cooking surface. For higher ceilings, a Stainless Steel Chimney
Extension Kit Part Number W10272070 is available from your
dealer or an authorized parts distributor. The chimney extension
replaces the upper chimney shipped with the range hood.

IMPORTANT:

Minimum distance "X": 27" (68.6 cm) from electric cooking
surface.
Minimum distance "X": 30" (76.2 cm) from gas cooking
surfaces.
Suggested maximum distance "X": 36" (91.4 cm)

For vented installations, the chimneys can be adjusted for
ceilings between 7’ 11" (2.4 m) and 8' 8" (2.6 m).

For non-vented (recirculating) installations, the chimneys can
be adjusted for ceilings between 7’ 11" (2.4 m) and 9' 0" (2.7 m).

36" (91.4 cm)

10

¹⁄₈

"

(25.8 cm)

20" (50.8 cm)

14

¹⁄₈

"

(35.9 cm)

*28

¹⁵⁄₁₆

" (73.4 cm) min.

42

³⁄₁₆

" (107.2 cm) max.

**28

⁷⁄₈

" (73.3 cm) min.

38

⁷⁄₁₆

" (97.6 cm) max.

8

¹⁄₁₆

"

(20.4 cm)

8

¹⁄₈

"

(20.7 cm)

7

¹⁄₄

" (18.4 cm)

6⁵⁄₈

" (16.8 cm)

2" (5.1 cm) min.
6" (15.2 cm) min.*

Centerline

Side

cabinet

Side

cabinet

Vent and power

supply cable

entry location

Cooking surface

36" (91.4 cm)

15" (38.1 cm)

7

³⁄₈

" (18.8 cm)

"X"

bottom of

canopy

to cooking

surface

Advertising