Components (generator), Figure 3. generator components – Multiquip Portable Generator (Honda GX340 Gasoline Engine) GAC-6HZR Manuel d'utilisation
Page 17

gaC6HZR 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 17
COMpOnents (generatOr)
120V
240V
ON
OFF
ON
OFF
120
V
GAC-6HZR
POWERED by
HONDA
6000
OFF
GFCI CIRCUIT
BREAKER
1
2
3
4
5
6
7
8
9
AC CIRCUIT BREAKER
INTERRUPTEUR DE COURANT CA
INTERRUPTEUR
DE OPERATION
OPERATION
SWITCH
CONTROL
DE RALENTI
IDLE
CONTROL
MARCHE
AC VOLTMETER
VOLTOMETRE CA
Figure 3. Generator Components
1.
main Breaker – This 2-pole circuit breaker (120/240V,
21 amps) protects the generator from short circuiting
or overloading. When starting the generator always
have the circuit breaker placed in the "
OFF" position.
2.
aC-voltmeter – This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator
OFF and consult your
authorized Multiquip service dealer.
3.
gFCi Breaker – This single pole circuit breaker (120V,
15 amps) protects the GFCI receptacle. When starting
the generator always have the circuit breaker placed
in the "
OFF" position.
4.
idle Control switch – The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched “
ON”, the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
5.
Operation switch – Place switch in the "ON" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "OFF" position (down).
6.
ground – This ground connection point should be
connect to a good earth ground (ground rod).
7.
240v Output Receptacle – NEMA L6-20R twist-lock
receptacle will provide 240V, 20 amps, 60 Hz.
8.
120v Output Receptacle – NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
9.
gFCi duplex Receptacle – NEMA 5-15R, GFCI
receptacle will provide 120V, 15 amps.