Recommended spacing for custom undercounter installation

The dimensions shown are for the recommended spacing.
Custom undercounter installation - Washer only

27"

(686 mm)

1"

(25 mm)

1"

(25 mm)

2" (50 mm)

36" min.

(914 mm)

Recommended spacing for recessed or closet installation, with or

without a pedestal

The dimensions shown are for the recommended spacing.
Recessed area or closet installation

3"

(76 mm)

3"

(76 mm)

34" min.

(864 mm)

48 in.

2

*

(310 cm

2

)

24 in.

2

*

(155 cm

2

)

1"

(25 mm)

4"
(102 mm)

30

1/2

"

(775 mm)

A. Side view - closet or confined area

B. Closet door with vents

Recessed or closet installation - Washer on pedestal

1"

(25 mm)

4"
(102 mm)

18" min.

(457 mm)

30

1/2

"

(775 mm)

1"

(25 mm)

27

"

(686 mm)

A. Recessed area

B. Side view - closet or confined area

Recommended spacing for recessed or closet installation, with

stacked washer and dryer

The dimensions shown are for the recommended spacing.

3"

(76 mm)

3"

(76 mm)

48 in.

2

*

(310 cm

2

)

24 in.

2

*

(155 cm

2

)

27"

(686 mm)

1"***

(25 mm)

1" (25 mm)

12" (305 mm)

1"***

(25 mm)

5

1

/

4

"**

(133 mm)

72"

(1829 mm)

*Min. top and bottom air openings for closet door.
**External exhaust elbow requires additional space.
***Wall, door, and floor molding may require additional spacing.

Recommended spacing for cabinet installation

The dimensions shown are for the recommended spacing.
For cabinet installation, with a door, the minimum ventilation

openings in the top are required.

1"

(25 mm)

(178 mm)

7"

(178 mm)

7"

(229 mm)

9"

(102 mm)

4"

(25 mm)

1"

(686 mm)

27

"

(775 mm)

30

1/2

"

Drain System

The washer can be installed using the standpipe drain system (floor

or wall), the laundry tub drain system, or the floor drain system.

Select the drain hose installation method you need. See “Tools and

Parts.”

Standpipe drain system - wall or floor (views A & B)

The standpipe drain requires a minimum diameter standpipe of

2" (50 mm). The minimum carry-away capacity can be no less than

17 gal. (64 L) per minute.