The Vent system chart provides venting requirements that will help to achieve the best drying
performance.

Vent system chart

Install Vent System

1. Install exhaust hood. Use caulking compound to seal exterior wall opening around

exhaust hood.

2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust

hood with 4" (10.2 cm) clamp.

3. Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in

“Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior of the vent to secure vent.

Install Leveling Legs

1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place

cardboard under the entire back edge of the dryer.

2. Firmly grasp the body of the dryer (not the top or console panel). Gently lay the dryer on

the cardboard. See illustration.

3. Examine the leveling legs. Find the diamond marking.

4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the

diamond marking is no longer visible.

5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners.

Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent or gas line.

For mobile home use

Gas dryers must be securely fastened to the floor.

Mobile home installations require a Mobile Home Installation Kit. See “Tools and Parts”
section for information on ordering.

Make Gas Connection

1. Remove the red cap from the gas pipe.
2. Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound

on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there
are no kinks.

NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action
of LP gas. Do not use TEFLON

®†

tape.

Number of 90º
turns or elbows

Type of vent

Box or louvered
hoods

Angled
hoods

0

Rigid metal
Flexible metal

64 ft (20 m)
36 ft (11 m)

58 ft (17.7 m)
28 ft (8.5 m)

1

Rigid metal
Flexible metal

54 ft (16.5 m)
31 ft (9.4 m)

48 ft (14.6 m)
23 ft (7 m)

2

Rigid metal
Flexible metal

44 ft (13.4 m)
27 ft (8.2 m)

38 ft (11.6 m)
19 ft (5.8 m)

3

Rigid metal
Flexible metal

35 ft (10.7 m)
25 ft (7.6 m)

29 ft (8.8 m)
17 ft (5.2 m)

4

Rigid metal
Flexible metal

27 ft (8.2 m)
23 ft (7 m)

21 ft (6.4 m)
15 ft (4.6 m)

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

A. Flared male thread

B. Non-flared male thread

A

B

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.