FRIGIDAIRE 134940500A Manuel d'utilisation

Page 11

Advertising
background image

11

4. Thread a U.L. approved 30 amp power cord, NEMA 14-30

type ST or SRDT through the strain relief.

5. Attach the green power cord ground wire to the cabinet with

the green ground screw.

6. Attach the white (neutral) power cord conductor from the

power cord and the neutral ground wire from the dryer harness

to the silver-colored center terminal on the terminal block.

Tighten the screw securely.

7. Attach the red and black power cord conductors to the outer
brass-colored terminals on the terminal block.

Do not make a sharp bend or crimp wiring/

conductor at the connections.

8. Tighten the screws securing the cord restraint firmly against

the power cord.

9. Tighten the strain relief nut securely so the strain relief does

not turn.

10.Reinstall the terminal block access cover.

STRAIN

RELIEF

MOUNTING

BRACKET

NUT

TIGHTEN
NUT
TO THESE
THREADS

POWER
CORD

RED

WHITE

BLACK

TERMINAL
BLOCK

SILVER TERMINAL

GREEN
GROUND
SCREW

GREEN POWER CORD
GROUND WIRE

NEUTRAL
GROUND
WIRE

ELECTRICAL CONNECTIONS FOR 4-WIRE SYSTEM

USA ELECTRIC Dryer

1. Remove the screws securing the terminal block access

cover and the strain relief mounting bracket located on the
back of the dryer upper corner.

2. Install a U.L. approved strain relief in the entry hole of the

mounting bracket. Finger tighten the nut only at this time.

3. Remove the ground wire from the green ground screw

located above the terminal block.

RED

BLACK

WHITE

GREEN

30 AMP NEMA 14-30 TYPE SRDT OR ST

TYPICAL 4
CONDUCTOR

TYPICAL 4
CONDUCTOR

Printed in U.S.A.

1. Remove the screws securing the terminal block access

cover and the strain relief mounting bracket located on the
back of the dryer upper corner.

2. Install a U.L. approved strain relief into the power cord entry

hole of the mounting bracket. Finger tighten the nut only at
this time.

3. Thread a U.L. approved 30 amp. power cord, NEMA 10-30

type SRDT, through the strain relief.

4. Attach the power cord neutral (center wire) conductor to the

silver colored center terminal on the terminal block. Tighten
the screw securely.

5. Attach the remaining two power cord outer conductors to

the outer brass colored terminals on the terminal block.
Tighten both screws securely.

Do not make a sharp bend or crimp wiring/

conductor at connections.

6. Reattach the strain relief mounting bracket to the back of

the dryer with two screws. Tighten screws securely.

7. Tighten the screws securing the cord restraint firmly against

the power cord.

8. Tighten the strain relief nut securely so that the strain relief

does not turn.

9. Reinstall the terminal block cover.

POWER CORD

TIGHTEN NUT
TO THESE
THREADS

STRAIN
RELIEF
MOUNTING
BRACKET

GREEN
GROUND
SCREW

NUT

NEUTRAL
GROUND
WIRE

SILVER
TERMINAL

ELECTRICAL CONNECTIONS

FOR 3-WIRE SYSTEM

USA ELECTRIC Dryer

Advertising
Ce manuel est liée aux produits suivants: