WIRING BOX

COVER

FIG. 17

LINE IN 120 VOLTS - 60 HZ

WIRE CLAMP

BLK-BLK

WHT-WHT

GRN-GRN

WIRING

Note: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards.

This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.

1. Remove the (2) screws of the upper flue and move the upper flue towards the bottom.
2. Feed 6” of power cable through the top opening of the support frame bracket (installed on ceiling) and into the wiring

box. For the Non-Ducted Hoods, do not use the upper hole of the wiring box.
Secure cable to the wiring box using an appropriate connector.

3. Feed the range hoods power cable through the lower hole of the wiring box (use a wire clamp located in the Hardware

Package.

4. Make electrical connections. Wire white-to-white, black-to-black and green-to-green.
5. Push all wiring inside the wiring box. Install the wiring box cover with (2) 3.9x9.5mm screws and (2) serrated washers

making sure wires are not pinched.

6. Tuck excess power cable inside the flue.
7. Reinstall the upper flue.