PREPARE THE WALL

1. Disconnect and move freestanding range from cabinet open-

ing to provide easier access to rear wall. Put a thick, protective

covering over cooktop, set-in range or countertop to protect from

damage or dirt.

2. Determine and clearly mark with a pencil the center line on the

wall where the rangehood will be installed.

3. Based on your ceiling height and/or personal preference, deter-

mine the distance you would like between the bottom of the hood

and the cooktop (distance X in FIGURE 4A OR 4B). Draw a

horizontal line the height of distance X plus 12 3/8" (as indicated

in FIGURE 5).

FIGURE 5

3. Hook the body on to the MOUNTING SCREWS (D in FIG-

URE 7) and fully tighten the MOUNTING SCREWS.

4. Adjust the leveling screws to level the CANOPY SEC-

TION.

5. For ducted installations, the DAMPER (H in FIGURE 1)

must be attached to the exhaust opening on the top of the

CANOPY SECTION. Connect the ductwork and seal all

connections with duct tape.

PROCEED TO "FOR ALL INSTALLATIONS" ON NEXT

PAGE

FIGURE 6

7. For the most secure installation, the MOUNTING SCREWS (D)

which mount the CANOPY SECTION (A in FIGURE 1) should be

installed into wood. Mark the wall along the horizontal line 4 9/16"

in from the center line on either side (as indicated in FIGURE 5A

or 5B) and install the MOUNTING SCREWS into the wall leaving

about 1/4" gap between the wall and the head of the screw.

8. For ducted installations, determine and make all necessary

cuts in the wall for the ductwork. Install the ductwork before the

rangehood.

9. Determine the proper location for the Power Supply Cable by

making sure it:

1) Allows the LOWER CHIMNEY COVER to hide the Field Wiring

Compartment.

2) Does not have ductwork blocking your access to the Field Wiring

Compartment.

Use a 1 1/4" Drill Bit to make this hole. Run the Power Supply

Cable. Use caulking to seal around the hole. DO NOT turn on

the power until installation is complete.

INSTALL THE RANGEHOOD

4. Place the UPPER CHIMNEY MOUNTING BRACKET (E) on

the wall as shown 1/16" from the ceiling, aligning the center notch

with the vertical center line. Mark the wall at the centers of the

holes in the bracket.

5. Place the LOWER CHIMNEY MOUNTING BRACKET (E) on

the wall as shown at 16 1/8" below the upper bracket, aligning

the center notch with the vertical center line. Mark the wall at the

centers of the holes in the bracket.

6. Install the CHIMNEY MOUNTING BRACKETS (E) on the wall

using the MOUNTING SCREWS (D) provided.

1. Remove the grease

filters from the unit by

pulling the knob forward

while turning it to the

left, releasing the lock-

ing lever.

2. Before mounting the CANOPY SECTION, tighten the two

leveling screws located near the CANOPY SECTION mounting

points as indicated in FIGURE 7.

FIGURE 7

Advertising