Security Light with
Motion-activated Sensor

Models 52-4075 / 52-4076

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified elec-
trician. Please check the codes in your area.

• This product is intended for use with a junction box

marked for use in wet locations.

• The backplate has knockouts so the sensor can be

mounted on most junction boxes.

• In some applications a universal adaptor plate may

be needed. Adaptors are available at home centers
and electrical supply stores.

Cover

Plate

Light Control

Lamp Holders

Sensor

2 Wire

Connectors

Gasket

4 Mounting

Screws (2 sizes)

This package includes:

OPERATION

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This product is ENERGY STAR

®

compliant

when used with 120 Watt bulbs.

Mode:

On-Time:

Works:

Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

x

Manual

Until Dawn*

x

Installation and Operating