RTH7400/RTH7500 Series

25

69-2487EF—01

Troubleshooting

SETUP

WIRING

ASSIST

ANCE

TROUBLESHOOTING

Heating or cool-

ing system does

not respond

Press SYSTEM to set system to Heat.
Make sure the temperature is set higher
than the Inside temperature.
Press SYSTEM to set system to Cool.
Make sure the temperature is set lower
than the Inside temperature.
Check circuit breaker and reset if
necessary.
Make sure power switch at heating &
cooling system is on.
Make sure furnace door is closed
securely.
Wait 5 minutes for the system to

“Wait” appears

on the screen

Compressor protection feature is
engaged. Wait 5 minutes for the system
to restart safely, without damage to the
compressor.

Heat pump is-

sues cool air in

heat mode, or

warm air in cool

mode

Check Function 0190: Heat Pump
Changeover Valve to make sure it is
properly configured for your system
(see page 17).