F300E ELECTRONIC AIR CLEANER WITH ENHANCED FILTRATION

68-0240EF—3

14

WARNING

Electric Shock Hazard.

Can cause personal injury.

Only a trained service technician should perform the

following procedure.

2. Move J5 shorting bar. This will reduce ozone production

about 20 to 25 percent and reduce efficiency about

seven to ten percent, depending on actual airflow deliv-

ered by the furnace blower.

a. Unplug or disconnect power supply to the air

cleaner.

b. Open the access door.

c. Remove the power box cover. See Fig.16.

d. Locate J5 shorting bar on the power supply. See

Fig. 17. Remove the shorting bar and reinstall on

only one pin.

NOTE: The ozone will be reduced, but the shorting bar is

available for reinstallation if needed.

e. Replace the power supply cover and access the

door. Turn on the power.

f. Repeat checkout procedure before leaving the job.