Electrolux 736684 Manuel d'utilisation

Page 24

Advertising
background image

2 4

buzzer:

buzzer activated

WHAT IS RECORDED?

Press

HACCP

the buzzer goes off; press again for 5

seconds until the alarm (AL1) is displayed.

Press again

HACCP

the temperature, start date and

time are given in a message: “TEMP 78.8F/26C Start 17.05

10-10-99 End——”.

b) The alarm has already occurred

41˚/5˚

50˚/10˚

59˚/15˚

68˚/20˚

77˚/25˚ Temperature ˚F/˚C

Critical temperature

Critical temperature

17:00 18:00

16:00

19:00

20:00 21:00

22:00

time

CHECKING

display:

the message “TEMP” is displayed

buzzer:

buzzer activated

WHAT IS RECORDED?

Press

HACCP

the buzzer goes off; press again for 5

seconds until the alarm (AL1) is displayed.

Press again

HACCP

the temperature, start date and time

are given in a message: “TEMP 78.8F/26C Start 17.05 10-10-
99 End——”
.

To access the recorded HACCP alarms press the

button

HACCP

for 4 seconds; the display will now show

HISt and then AL_1 (alarm symbol); this shows the last alarm
for the max. compartment temperature stored in the PCB. Press

the button

HACCP

to display the value of the last alarm

for max. compartment temperature. The display now shows:
- TEMP 78.8F/26C (type and value of the alarm for max.

compartment temperature)

- Start date and time (alarm activation date and time)
- End date and time (alarm end date and time)

Press the button

HACCP

to display the alarm (AL1)

symbol again. Press the button

HACCP

to display the

next alarm for max. compartment temperature. If no button is
pressed within 10 seconds the HACCP section is quitted.

· CHECKING OLD ALARMS

Hold down the button

HACCP

:: the display shows AL1

(last alarm); to select the other alarms (AL2, AL3,...) press

.

· FOR HOW LONG ARE THE ALARMS STORED?
Permanently, at least while there is space in the memory (max.
number of alarms recorded: 99).

C.1.7.3 SERVICE ALARMS

To access the SERVICE ALARMS press the

button

for 4 seconds; the display shows the first

SERVICE ALARM stored in the electronic panel, e.g. “b1” (door

open). Press the button

to display the next

SERVICE ALARM stored in the electronic panel. If other SERVICE
ALARMS are not stored in the electronic panel, the display shows
“——”. If no button is pressed within 5 seconds, the SERVICE

ALARMS section is quitted.

· FOR HOW LONG ARE THE ALARMS STORED?

Until the entire list of stored alarms is displayed. After which
they will remain stored until another alarm occurs: resetting is
automatic.

· ALARM SIGNALING
- alarm button LED flashing

- buzzer activated (acoustic alarm)

· CHECKING ALARMS

Hold down the button

the display shows the last

alarm that occurred (a message) and the buzzer is deactivated.

To reset the alarm, press

until “——” is

displayed.