Warning, Maintenance, Ventilation – Enerco HEATSTAR 2000ID 3000ID Manuel d'utilisation

Page 5

Advertising
background image

5

operating Instructions and owner’s Manual

eNeRCo GRoUP, INC. |Indirect Fired Portable Heater

5

4

A

3

2

D

C

1

B

The hot air heaters with wheels must be wheeled. The suspended
version which has no wheels must be transported with adequate
machinery.

Maintenance

Preventive and regular maintenance will ensure a long trouble free
life to your heater.

warning

• Never service heater while it is plugged in, operating or hot.

Severe burns or electrical shock can occur.

every 50 hours of operation: disassemble filter and wash with
clean oil, remove upper body parts and clean inside and ventilator
with compressed air, check correct attachment of H.T. connectors
to the electrodes and check H.T. cables, remove burner assembly,
clean and check electrode settings, adjust according to scheme
“GAP oF eleCTRoDeS”.

Flue connections diagram

VentilatiOn

A

6

2

D

C

1

B

5

E

description

a) Minimal 39”

B) Minimal 39”

c) The shortest

d) The same or bigger than the smokes outlet diameter of

heater

e) Minimal 1m

1) Anti-wind device provided with the heater

2) Horizontal crossing with minimal upside angle pitch of 5°

3) Chimney 8” x 8” of minimal inside measure

4) Chimney anti-explosion flap door

5) external seating wall

6) Chimney ending H shape

n.B. above recommendation indicative only. Have your
installation checked by local authority.

6 “

Advertising
Ce manuel est liée aux produits suivants: