Malfunction display and solutions

When the washer is in trouble, please contact local service office or the sales service
department of our company and the customer should not dismantle the machine
without permission.
If the washer can not work normally, and the abnormal indication is shown in the digital
display window or the machine alarms, please check and correct as follows.

18

Water injection for about
30 minutes, but do not
reach preset water level

“E1” flares, and

other lights are

turned off.

After draining for 10
minutes, does not finish
draining.

Fault

Cause of fault

Indication

Alarm of the
buzzing sound

Stopping alarm

Alarm for
water inlet

Alarm for
opening lid

Imbalance

alarm

Drain

alarm

“E2” flares, and
other lights are
turned off.

“E3” flares, and
other lights are
turned off.

“E4” flares, and
other lights are
turned off.

“E5” flares, and
All water lever
lights flash.

Overflow

alarm

Note:

1: alarm removed, the return to the status before the alarm; E3 failures appear in the same trip.

2: overflow alarm, automatic water drain valve open until the manual intervention contact failure.

Open the lid after starting
the delay time. Open the lid
when the washer is spinning.
Open the lid when entering
into the child lock state.

Water level is higher than
rated overflow level

1:Power off


2:repair

Technical specifications

Technical specifications

601X615X1015

45kg

4.2A

2.5Cu.ft

120

Current
value

Drum Size

Not normally open or
unlocked door

the door can be open only by
pull up the power when the
door is locked, and it can
power-off and alarm-cleared
by press the power key when
the door lock is open.

“E6” flares,

Door-lock

failure

19