operating Instructions and owner’s manual

eNeRCo GRoUP, INC. |Indirect Fired Portable Heater

IMpORTANT

Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.

gENERAL RECOMMENDATIONS

The heater is designed and approved for use as a construction
heater in accordance with Standard ANSI Z83.7 - CGA 2.14.
Intended use is the temporary heating of buildings or structures
under construction, alteration or repair.

wARNINg

CHeCK WITH YoUR loCAl FIRe sAFeTY AUTHoRITY IF

YoU HAVe QUesTIoNs ABoUT APPlICATIoNs.

Here are a few general guidelines which should be followed:

• Follow the instructions in this booklet very carefully.
• Don’t install the heater in places where there may be a risk

of fire or explosion.

• Inflammable material should be kept at a safe distance from

the heater (minimum 6 feet).

• All fire prevention regulations must be adhered to.
• The room or building which is being heated must be

sufficiently ventilated so that the heater has enough air to
function properly.

• The heater must be near a chimney or chimney flue and a

suitable electric switchboard.

• Don’t let animals or children near the heater.
• Make sure heater is inspected before each use, and at least

annually by a qualified service person.

• After use make sure the disconnecting switch is off. When

using any type of space heater it is obligatory: not to
exceed the maximum level of heat output of the furnace
(“TeCHNICAl sPeCIFICATIoNs TABle”).

• To make sure that there is adequate air circulation and air

supply to the heater and that nothing is obstructing the
aspiration and expulsion of air; movement of air may be
obstructed in various ways including placing covers or other
objects on the heater or positioning the heater too near a
wall or other large object. If the airflow is not adequate, the
combustion chamber will overheat and the overheat safety
thermostat l1 will turn the burner off and on continuously
(“TRoUBlesHooTING”).

TECHNICAL SPECIFICATIONS

4000ID

4000ID

7000ID

HD7000ID

Heat input

[kBTU/h]

400

400

700

700

Air flow

[cfm]

4.240

4.240

7.420

7.420

Heat output

[kBTU/h]

340

340

595

595

Oil N”2 Max fuel
consumption

[LBH]

20.4

20.4

35.8

35.8

Natural gas fuel
consumption

[CFH]

391.4

391.4

684.9

684.9

propane fuel consumption

[CFH]

157.0

157.0

274.7

274.7

power supply

phase

1

1

1

1

Voltage

[V]

120

220

220

220

Frequency

[Hz]

60

60

60

60

Electric consumption

[W]

1.240

1.760

2.120

2.300

[A]

13.5

14.5/5.8

7.0

14.8

Diesel burner model

Riello 40 F10

Riello 40 F15

Nozzle

[USgalll1]

2.25 gpH 600 B

2.25 gpH 60’ B

3.50 gpH 60’ B

3.50 gpH 60’ B

gas burner model
(nalural gas or propane)

Riello 40 g400

Riello 40 g750

gas supply pressure:
natural gas

min 4” w.c. max 10” w.c.

min 7” w.c. max 14” w.c.

gas supply pressure:
propane

min 8” w.c. max 13” w.c.

min 8” w.c max 14” w.c.

Static pressure

[lnWC]

0.4

0.8

0.4

0.8

Flue diameter

[In]

5.9

5.9

7.9

7.9

Compulsory flue draft

[lnWC]

0.05

0.05

0.05

0.05

Maximum air temperature

°F

250.0

250.0

250.0

250.0

Dimensions. L x w x H

[In]

72x31x43

82x31x43

85x35x53

101x35x53

weight

[Ib]

353

364

550

562

832 (HD Version)