TROUBLESHOOTING GUIDE

PROBLEM

Engine will
not start (see
Engine Manual
for further
engine
troubleshooting)

No or low

pressure

(initial use)

CAUSE

CORRECTION

No fuel.

Add Fuel.

Pressure builds up after two pulls
on the recoil starter or after initial
use.

Squeeze gun trigger to relieve

pressure.

Spark plug wire not attached.

Attach spark plug wire.

Spray wand not in high pressure.

See How to Use Spray Wand

instructions in the Operation

Section.

Low water supply.

Water supply must be at least 5

GPM @ 20 PSI.

Leak at high pressure hose fitting.

Repair leak. Apply sealant tape

if necessary.

Nozzle obstructed.

See Nozzle Cleaning instructions

in the Maintenance section.

Water filter screen clogged.

Remove and clean filter.

Air in hose.

Turn off the engine, then the

water supply. Disconnect the

water supply from the pump inlet

and turn the water supply on

to remove all air from the hose.

When there is a steady stream

of water present, turn water

supply off. Re-connect water

supply to pump inlet and turn on

water supply. Squeeze trigger to

remove remaining air

High pressure hose is too long.

Use high pressure hose under

100'.

Choke lever in the "Choke"
position on a "hot" engine or an
engine that has been exposed to
thermal heat for a long period of
time.

Move choke lever to the "No

Choke" position.

Choke lever in the "Choke" position. Move choke lever to the "No

Choke" position.

Choke lever in the "No Choke"
position.

Move choke lever to the "Choke"

position.

Throttle control lever is not in the
"Fast" position.

Move throttle control lever to the

"Fast" position.

Advertising