Replacing the return

spring

Remove the starter housing (see “Replacing the starter

cable”).
Take the air guide off the starter housing (see “Replacing the

starter cable”).
De-tension the return spring on the cable drum

(see “Replacing

the starter cable”).
Take off circlip (1) (circlip pliers, see “Accessories”).
Remove the cable pulley (2).
Evenly lever the return spring (4) out of the catch using a screw-

driver or similar tool. Be extremely careful - the return spring

is under tension and can pop out of its housing!
CAUTION! Injury hazard! Wear eye protection and work

gloves when performing this work!

Replacement return springs are delivered already tensioned in

the housing. CAREFUL - the spring can pop out. If it does,

it can be put back in as shown in the diagram (observe the

direction of rotation).
Before installing the new return spring (4) in the starter hous-

ing, grease it lightly with multipurpose grease, Order No. 944

360 000. Then position it and press it until the tabs (5) engage

in the slots.
Do not grease the cable drum (2) or bearing journal!
Turn the cable pulley slightly when putting it back on, until you

hear it catch. Put the circlip back on.
Wind on the starter cable (see above under “Replacing the

starter cable”).
Reinstall the air guide (see above under “Replacing the starter

cable”)
When putting the starter housing back on, it may be necessary

to pull the starter handle slightly until the starting mechanism

engages.