5 EASY STEPS TO OPERATE YOUR ANGELCARE

®

MONITOR

Note:
• Test your Angelcare

®

Monitor BEFORE first-time use and then on a periodic basis.

When monitor is in use, DO NOT use crib mobile or other crib accessories that produce vibrations. Alarm will not sound as monitor is

still detecting movement.

The Angelcare

®

Monitor is perfectly safe. The Sensor Pad and its cord is entirely passive. They carry no electrical current and do not

radiate any form of energy. The Nursery Unit emits only very low power radio signals through its antenna. These signals do not present
a safety hazard.

• Your monitor can be used in any crib or sleeping area (that has no motion or vibration) designed to safely hold a baby.
• To monitor twins, you need two AC301 Movement & Sound Monitors or one AC301 Movement & Sound Monitor and one AC300 Movement only

monitor. You should have one nursery unit on Movement function and the other nursery unit on Sound/Movement/Tic or Sound/Movement. You

can use only one parent unit on the same channel. The sound monitor of one AC301 is sufficient to monitor both babies in the same room. Do
not use the Angelcare

®

to monitor movement of two babies in one crib or bassinet.

STEP 1. SENSOR PAD

Position Sensor Pad as illustrated (Figures 1 and 2). Connect the long Sensor Pad cord to the Nursery Unit (Figure 4). The printed side
of Sensor Pad MUST face up. DO NOT tuck thick bedding under the edges of the mattress.

The Sensor Pad must rest on a COMPLETELY FLAT AND RIGID SURFACE. Place a piece of 6 mm (1/4”) plywood to cover the full
size of the crib base. Make sure the sensor pad’s cord passes underneath the mattress as shown in figure 1.

STEP 2. NURSERY UNIT (TRANSMITTER)

• Insert 4 AAA batteries into Nursery Unit (for battery backup in case of power failure).
• Connect Sensor Pad to Nursery Unit (Figures 4 and 6).
• On the back of the Nursery Unit, select 1 of the 4 functions of how you want to monitor your baby from the Parents Unit:

Movement: To use the movement only function. This does not transmit any sound to the parent unit.
Sound/Movement/Tic: To hear sounds, see sound lights and hear a “Tic” sound with every movement baby makes.
Sound/Movement: To hear sounds, see sound lights function BUT without the “Tic” sound.
Sound: To hear sounds and see sound lights on Parents Unit.

• Connect AC adapter to Nursery Unit and plug adapter into an electrical outlet.

NOTE: The sensitivity adjustment has been preset. DO NOT ADJUST UNLESS NECESSARY. If poor capture of movement (red flashing
light) or false alarm occurs, consult the Movement Sensitivity Adjustment section.

STEP 3. PARENTS UNIT (RECEIVER)

Model AC301: Insert 3 AAA batteries into Parents Unit. Connect AC adapter to Parents Unit and plug adapter to an electrical outlet.

Model AC301-R: The pre-installed NiMh rechargeable batteries need to be charged for 15 hours continuously before first-time

use. To charge, connect the AC adapter to the Parents Unit. Plug AC adapter to an electrical outlet (Figure 3). The batteries will charge
as long as it is connected to a powered AC adapter. The position of the switches will not effect charging.

For longest battery life, recharge the Parents Unit when the orange Low Battery light flashes. Batteries need to be charged

for 12 hours continuously.

NOTE: Only the Parents Unit is rechargeable in Model AC301-R.

• Adjust the volume control to the desired level.

STEP 4. TO USE MONITOR

Place baby in crib and switch both units ON by selecting either channel A, B or C. If reception is not clear, switch to another channel.
Make sure both units are on the same channel. When removing baby from crib, switch Nursery Unit to the OFF position. If you forget
to switch OFF, a “pre-alarm Tic” will sound after 15 seconds as a reminder followed by an alarm 5 seconds later. To avoid feedback
(whistling sound), keep both units at least 3 meters apart (10 feet).

Note: When both units are turned ON, a “--“symbol will appear on the nursery unit temperature display screen. It will stay ON for 20
seconds. During this time the nursery unit is sending the settings to the parents unit. Once the room temperature is displayed on the
nursery unit, the monitor is ready to be used.

STEP 5. BATTERY MODE

• When unplugging AC adapter from each unit, make sure unit is switched OFF. Otherwise, unit will revert to battery mode.
• The monitor will revert to battery mode during a power failure only if batteries are inserted in both units. Insert batteries into Nursery

Unit and Parents Unit for Model AC301. When orange Low Battery indicator flashes, change batteries promptly (or recharge Parents
Unit for Model AC301-R).