Operation, Description of operation, Know your air compressor – Craftsman PERMANENTLY LUBRICATED 2-STAGE TWIN V PORTABLE AIR COMPRESSOR 919.7255 Manuel d'utilisation

Page 13

Advertising
background image

13- ENG

D24445

Tank Pressure Gauge: The tank
pressure gauge indicates the reserve
air pressure in the tank.
Regulator: Controls the air pressure
shown on the outlet pressure gauge.
Pull the knob out and turn clockwise
to increase pressure and
counterclockwise to decrease
pressure. When the desired pressure
is reached push knob in to lock in
place.
Universal Quick-Connect Body:
The universal quick-connect body
accepts the three most popular styles
of quick-connect plugs- Industrial,
automotive (Tru-flate), and ARO. One
hand push-to-connect operation
makes connections simple and easy.

Drain Valve: The drain valve is
located at the base of the air tank
and is used to drain condensation at
the end of each use.

Description of Operation

Become familiar with these controls
before operating the unit.
On/Auto/Off Switch: Turn this switch
ON to provide automatic power to
the pressure switch and OFF to
remove power at the end of each
use.
Pressure Switch: The pressure
switch automatically starts the motor
when the air tank pressure drops
below the factory set “cut-in”
pressure. It stops the motor when the
air tank pressure reaches the factory
set “cut-out” pressure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its “cut-out” pressure setting, the
safety valve will protect against high
pressure by “popping out” at its
factory set pressure (slightly higher
than the pressure switch “cut-out”
setting).
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air
pressure available at the outlet side
of the regulator. This pressure is
controlled by the regulator and is
always less than or equal to the tank
pressure.

Safety Valve

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.

On/Auto/Off
Switch

Regulator

Outlet
Pressure
Gauge

Tank Pressure Gauge

Pressure
Switch

Drain
Valve

Universal
Quick-
Connect
Body