troubleshooting chart

Symptom

possible cause(s)

corrective action

Compressor will not

run

1. Loss of power or overheating

1. Check for proper use of extension cord (see EXTENSION CORDS,

page 5)

2. No electrical power

2. Plugged in? Check fuse/breaker or motor overload

3. Blown fuse

3. Replace blown fuse in household circuit

4. Breaker open

4. Reset, determining why problem happened

5. Thermal overload open

5. Motor will restart when cool; turn off compressor and wait 20

minutes.

6. Pressure switch bad

6. Replace

Motor hums but

cannot run or runs

slowly

1. Low voltage

1. Check with voltmeter

2. Wrong gauge wire or length of

extension cord

2. Check gauge chart, under Installation for proper gauge wire and

cord length

3. Shorted or open motor winding

3. Replace motor

4. Defective check valve or unloader

4. Replace or repair

Fuses blow/circuit

breaker trips

repeatedly

1. Incorrect size fuse, circuit overloaded

1. Check for proper fuse, use time-delay fuse. Disconnect other

electrical appliances from circuit or operate compressor on its

own branch circuit

2. Wrong gauge wire or length of

extension cord

2. Check gauge chart, under Installation

3. Defective check valve or under loader

3. Replace or repair

Thermal overload

protector cuts out

repeatedly

1. Low voltage

1. Check with voltmeter

2. Clogged air filter

2. Clean filter (see Maintenance section)

3. Lack of proper ventilation/room

temperature too high

3. Move compressor to well ventilated area

4. Wrong gauge wire or length of

extension cord

4. Check gauge chart, under Installation

Air receiver pressure

drops when

compressor shuts off

1. Loose connections (fittings, tubing,

etc.)

1. Check all connections with soap and water solution and tighten

2. Loose drain lock

2. Tighten

3. Check valve leaking

3. Disassemble check valve assembly, clean or replace

Do not disassemble check valve

with air in tank; bleed tank first.

Excessive moisture in

discharge air

1. Excessive water in air receiver

1. Drain receiver

2. High humidity

2. Move to area of less humidity; use air line filter

Compressor runs

continuously

1. Defective pressure switch

1. Replace switch

2. Excessive air usage

2. Decrease air usage; compressor not large enough for a

requirement

3. Check valve leaking

3. Disassemble check valve assembly, clean or replace

Compressor vibrates

Loose mounting bolts

Tighten

Air output lower

than normal

1. Broken inlet valves

1. Have authorized service representative repair unit

2. Intake filter dirty

2. Clean or replace intake filter

3. Connections leaking

3. Tighten connections

Maintenance

(continued)

This compressor is

equipped with a

manual reset thermal overload protector
which will shut off motor if it becomes
overheated.

If thermal overload protector shuts
motor off frequently look for the
following causes.
1. Low voltage.

2. Wrong gauge wire or length of

extension cord.

3. Clogged air filter.
4. Lack of proper ventilation.

The motor must be

allowed to cool down

before start-up is possible. The motor will
automatically restart without warning if
left plugged into electrical outlet, if the
motor is turned on.

StoraGe
1. When not in use, hose and

compressor should be stored in a
cool dry place.

2. Tank should be drained of moisture.
3. Hose should be disconnected and

hung open ends down to allow any
moisture to drain.