Bradford White UDH-75T-50FR-3N Manuel d'utilisation

Page 3

Advertising
background image

3

IMPORTANT

When the following instructions specify, to seal a vent-air intake joint,
use only Permatex Ultra Blue RTV Silicone sealant. A tube of Permatex
Ultra Blue RTV Silicone sealant is supplied with every direct vent water
heater and each optional vent-air intake kit. Make sure that all joints are
completely sealed.

VENT-AIR INTAKE SYSTEM INSTALLATION

Tools Required For Vent-Air Intake Installation

The following minimum tools are required to properly install the vent-
air intake system. Note: Wall construction will determine tool usage.


Tape Measure

Drill

3/16 inch (4.5 mm) Diameter Drill Bit(s)

Masonry Drill Bit(s) (For Poured Concrete, Concrete Block and Brick

Wall Construction)

Reciprocating Saw w/appropriate Blade(s) (Dependent on Wall

Construction)

Chisel (For Poured Concrete, Concrete Block and Brick Wall

Construction)

Hammer (For Poured Concrete, Concrete Block and Brick Wall
Construction)

1/4 & 5/16 inch Nut Drivers (Preferred) or Slotted Head Screwdriver
Phillips Head Screwdriver

WARNING

The vent-air intake system must be properly installed. Failure to properly
install the vent-air intake system could result in property damage,
personal injury or death.

DO NOT install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.

IMPORTANT – Refer to parts list in the back of this manual
and become familiar with the parts named in kit.

WARNING

The vent-air intake terminal must be installed through an outside wall in a horizontal
position. This direct vent water heater is not designed for through the roof vertical
venting.

Advertising
Ce manuel est liée aux produits suivants: