D30339

CUSTOMER RESPONSIBILITIES TABLE

MAINTENANCE TASK

PRESSURE WASHER

ENGINE

check/clean inlet screen

check high pressure hose

check soap and chemical
hose and filter
check gun and wand for leaks

check oil level

change oil

check air cleaner

clean/replace spark plug

prepare for storage

Before

each use

Every 25
hours or

yearly

Every 50
hours or

yearly

Every 100

hours or

yearly

Prepare unit for storage if it is to remain idle for longer
than 30 days

X

X

X

X

X

X**

X*

X

clean debris

X

clean air cooling system

X

clean combustion chamber

X

* Change oil after first 5 to 8 hours of use, then every 50 hours or every

season. Change oil every 25 hours when operating the engine under heavy
load or in high temperatures.

** Clean more often under conditions of dust or airborne debris. Replace air

cleaner parts, if very dirty.

5.

If needed, add oil slowly and
recheck. Do not over fill.

NOTE: Use a high quality detergent oil
classified “For Service SF, SG, SH,
SJ” or higher, such as SAE 30.

NOTE: Other viscosities shown in the
chart may be used when the average
temperature in your area is within the
recommended range.

6.

Replace filler cap/dipstick.

ENGINE

To Check Oil

1.

Shut down engine and place on a
level surface.

2.

Remove filler cap/dipstick and
wipe it clean.

3.

Replace and tighten dipstick.
Remove and check oil level.

4.

Oil level should be at the FULL
line on dipstick.

F -20

0

20

40

60

80

100

C -30

-20

-10

0

10

20

30

40

STARTING TEMPERATURES RANGE