Offset vertical enclosures – Thetford 1210 Series GE - Current Manuel d'utilisation

Page 10

Advertising
background image

Installation Manual 10

Offset vertical enclosures:

If the enclosure depth is 24 inches or more and less than 25 inches (See Art01783):

- Install an angled top baffle [172] between the top rear edge of the refrigerator and the

inside edge of the upper exhaust vent opening.

- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the

refrigerator.

- Make sure that the angled top baffle is no more than 45° from vertical [20].

- Install an inside corner baffle [173] between the outside edge of the upper exhaust

vent opening and either the side wall of the vehicle or the solid box baffle (depending

on the vehicle design).

If the enclosure depth is 25 inches or more and less than 26 inches (See Art01784):

- Install an angled top baffle [172] between the top rear edge of the refrigerator and the

inside edge of the upper exhaust vent opening.

- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the

refrigerator.

- Make sure that the angled top baffle is no more than 45° from vertical [20].

- Install an inside corner baffle [173] between the outside edge of the upper exhaust

vent opening and either the side wall of the vehicle or the solid box baffle (depending

on the vehicle design).

- Install a condenser baffle [16] at the lowest edge of the condenser of the refrigerator.

- Make sure that the condenser baffle is 1 inch or less [19] from the condenser.

- Install an absorber baffle [171] 18 inches to 18 1/2 inches above the bottom of the

enclosure [17] (4 1/4 inches to 4 3/4 inches above the top of the lower intake vent

opening) [18] .

- Make sure that the absorber baffle is 1 inch or less [19] from the absorber.

Art01783

15

20

172

173

Art01784

20

15

172

173

10
16
19

18

17

171

19

11

Advertising