To open the door manually, Care of your opener – Chamberlain Security + 3850PC Manuel d'utilisation

Page 30

Advertising
background image

30

To Open the Door Manually

The door should be fully closed if
possible. Pull down on the
emergency release handle and lift
the door manually. To reconnect
the door to the opener, press the
door control push bar.

The lockout feature prevents the
trolley from reconnecting
automatically. Pull the emergency
release handle down and back
(toward the opener). The door can
then be raised and lowered
manually as often as necessary.
To disengage the lockout feature,
pull the handle straight down. The
trolley will reconnect on the next
UP or DOWN operation, either manually or by using the
door control or remote.

Care of Your Opener

MAINTENANCE SCHEDULE

Once a Month

• Manually operate door. If it is unbalanced or binding, call

a trained door systems technician.

• Check to be sure door opens and closes fully. Adjust

limits and/or force if necessary. (See pages 23 and 24.)

• Repeat the safety reverse test. Make any necessary

adjustments. (See Adjustment Step 3.)

Once a Year

• Oil door rollers, bearings and hinges. The opener does

not require additional lubrication. Do not grease the door
tracks.

To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:
• If possible, use emergency release handle to disengage

trolley ONLY when garage door is CLOSED. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.

• NEVER use emergency release handle unless garage doorway

is clear of persons and obstructions.

• NEVER use handle to pull door open or closed. If rope knot

becomes untied, you could fall.

NOTICE

NOTICE

Trolley
Releas
Arm

Trolley
Release
Arm

Emergency
Release Handle
(Pull Down)

Emergency
Release Handle
(Down and Back)

LOCKOUT POSITION

MANUAL DISCONNECT

POSITION

Advertising