How to Start:

1. Turn the On/Auto/Off lever to

"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.

2. Pull the regulator knob out and

turn clockwise to increase pres-
sure. When the desired pressure
is reached push knob in to lock
in place. The compressor is
ready for use.

Before Each Start-Up:

1. Place On/Auto/Off lever to

"OFF".

2. Pull regulator knob out, turn

counter-clockwise until it stops.
Push knob in to lock in place.

3. Attach hose and accessories.

NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.

5. Run the compressor for 15 min-

utes. Make sure the drain valve
is open and there is minimal air
pressure build-up in tank.

6. After 15 minutes, close the drain

valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.

The compressor is now ready for use.

Risk of Bursting.

Too much air pres-

sure causes a hazardous risk of

bursting. Check the manufacturer’s

maximum pressure rating for air

tools and accessories. The regu-

lator outlet pressure must never

exceed the maximum pressure rat-

ing.