Wall Mounting Kit Installation Instructions

For Heat Exchanger Unit Heaters

(En français à l’endos.)

WARNING:

If the heater is installed on a structure that is to be transported, provide additional support for

the heater during transit. The suspended weight should not exceed 300lbs (136kg). Refer to the

owner’s manual for mounting specifications and conditions.

Check that your heater model number corresponds to the model number shown on the mounting kit carton

.

Installer required to supply:

A method to fasten the two Z-Sections  to the supporting structure. Four 3/8” diameter, grade 5

bolts are suggested, however, any method providing the same or greater strength may be used.

CONTENTS

Item Qty. Description

2 Z-Section

1 Arm Assembly

1 Mtg Attach Assy Bracket

4 Nut, 3/8 UNC

4 Bolt, 3/8 UNC x 1

4 Lock Washer, 3/8”

3 Bolt, 1/2 UNC x 1-1/4

3 Lock Washer, 1/2”

2 Nut, 1/2 UNC

1 Flat Washer, 1/2”

18” (457mm)

Recommended

mounting holes

12”

(307mm)

7-3/16”

(183mm)

���

21-13/16”

(554mm)

to wall

STEP 2
Bolt the Arm Assembly  to

the Z-Sections  using 3/8

UNC x 1 bolts, lock washers

and nuts

STEP 1
Fasten the Z-Sections  to a wall

that will support the heater’s weight

using installer supplied fasteners.

STEP 3
Bolt Mtg Attach Assy Bracket 

to the heater using 1/2 UNC x

1-1/4 bolts, lock washers, and

1/2 UNC nuts.

STEP 4
Lift the heater into place and fasten

it to the Arm Assembly  using a

1/2 UNC x 1-1/4 bolt, lock washer

and flat washer. This step will

require more than one person due

to the weight of the heater. Refer to

the owner’s manual for the weight

of the heater.

Heater may

be rotated as

indicated by

arrows

Printed in Canada. Copyright 2007. All rights reserved.