6. Cut the ring terminal off the pilot lead of the replace-

ment torch.

7. Remove the two screws from the Pilot Connector Plug.

Open the connector and insert the end of the Torch Pi-
lot Lead wire into either one of the outside terminals.
DO NOT insert pilot wire into center terminal.

In-

sert one end of the supplied Pilot Connector Jumper
Wire into the same terminal as the Torch Pilot Lead.
Insert the other end of the Pilot Connector Jumper Wire
into the other outside terminal. Re-install the two
screws. Connect the Pilot Connector Plug to the Power
Supply.

8. Connect the Negative / Plasma Lead from the replace-

ment torch to the Power Supply. Slide the protective
boot over the lead connection.

9. Connect the Control Connector Plug, with two connec-

tors, to the two mating connectors on the replacement
torch leads, see NOTE.

10. Connect the Control Connector Plug to the Power Sup-

ply.

11. Reinstall any covers removed, see WARNING.

12. Install the proper torch consumables for the Power Sup-

ply amperage.

13. Reconnect input power and turn ON the unit.

14. Set proper gas pressure or flow.

15. Test torch for proper operation.

WARNING

Make sure that the Control Connector Plug wires
DO NOT contact the Adapter Fitting after all leads
are connected.

NOTE

For Mechanized Systems refer to the Torch Control
Cable Wiring Diagrams in the Manual supplied with
the RPT Torch.