Se tx sel dmx s e tx sel dmx – Clay Paky ALPHA BEAM 700 (C61360) Manuel d'utilisation

Page 26

Advertising
background image

26

ALPHA BEAM 700

• LAMP CONTROL (only with option LAMP DMX On) - channel: 22

IMPORTANT: Alpha Beam 700 is not provided with hot restrike igniter

LAMP ON (FULL POWER)

LAMP ON (FULL POWER)

BIT

%

EFFECT

255

100

180

70.5

0

0.0

101

39.5

100

39.0

LAMP OFF

179

70.0

26

10.0

LAMP OFF

25

9.7

UNUSED RANGE

Lamp ignition after 5 s
in full power levels.

Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.

ON

ON
ON

OFF

ON

OFF

LAMP ON (HALF POWER)

LAMP ON (HALF POWER)

Immediate transition
from full to half power.

Immediate transition
from half to full power.

Lamp ignition not allowed
in half power.

• FUNCTION - channel: 20

BIT

%

EFFECT

255

100

52 20.5

51 20.0

39 15.0

26 10.0

13

5.0

0-12 0.0-4.7

LINEAR (DEFAULT)

UNUSED RANGE

UNUSED RANGE

CONVENTIONAL

NORMAL SPEED

FAST SPEED (DEFAULT)

DIMMER CURVE
FUNCTION

PAN-TILT
FUNCTION

• RESET - channel: 21

• TILT FINE - channel 19

Operation with option Invert Tilt

G

Off

(Pan conventionally represented at 0% and option Invert Pan

G

Off)

BIT

%

255

100

0

0.0

S

E

TX

SEL

DM X

S

E

TX

SEL

DMX

Operation with option Invert Tilt

G

On

(Pan conventionally represented at 0% and option Invert Pan

G

Off)

BIT

%

255

100

0

0.0

S

E

TX

SEL

DMX

S

E

TX

SEL

DMX

The functions are actived passing through the unused range and staying 5
seconds in necessary level.

EFFECT

BIT

243 – 255

240 – 242

237 – 239

234 – 236

231 – 233

228 – 230

225 – 227

222 – 224

219 – 221

216 – 218

213 – 215

210 – 212

207 – 209

204 – 206

128 – 203

77 – 127

26 – 76

0 – 25

95.0 – 100

94.0 – 94.7

93.0 – 93.7

91.7 – 92.5

90.5 – 91.2

89.5 – 90.0

88.2 – 89.0

87.0 – 88.0

86.0 – 86.7

84.7 – 85.5

83.7 – 84.2

82.5 – 83.2

81.2 – 82.0

80.0 – 81.0

50 – 79.5

30 – 49.7

10 – 29.7

0.0 – 9.7

%

COMPLETE RESET

Complete reset is activated passing throug the unused
range and staying 5 seconds in complete reset levels.

Rotating Gobo OFFSET 13

Rotating Gobo OFFSET 12

Rotating Gobo OFFSET 11

Rotating Gobo OFFSET 10

Rotating Gobo OFFSET 9

Rotating Gobo OFFSET 8

Rotating Gobo OFFSET 7

Rotating Gobo OFFSET 6

Rotating Gobo OFFSET 5

Rotating Gobo OFFSET 4

Rotating Gobo OFFSET 3

Rotating Gobo OFFSET 2

Rotating Gobo OFFSET 1

COMPLETE RESET

Complete reset is activated passing throug the unused
range and staying 5 seconds in complete reset levels.

PAN/TILT RESET

Pan/Tilt reset is activated passing throug the unused
range and staying 5 seconds in Pan/Tilt reset levels.

EFFECTS RESET

Effects reset is activated passing throug the unused
range and staying 5 seconds in Effects reset levels.

Unused range

Advertising